Quick Links - Also see the menu above and more choices on the right side of the blog (too much, but all good stuff)

\/ ...and now BIMbuilder.com Blog Posts... \/

Tuesday, April 6, 2010

Troubleshooting Wall Phasing - The Revit Clinic

Source: http://revitclinic.typepad.com/my_weblog/2010/04/troubleshooting-wall-phasing.html

I've included 3 important items to check in a view where walls may not appear to be following phasing settings. There are 3 videos below [with sound] for reference:

1. View Phase / Phase Filter Settings

First item to check is the Phase of the view under Properties > Phasing > Phase. Verify this is set as needed.

Next note the Phase Filter. Under Manage > Phases > Phase Filters find the phase filter on the list. For any category set to Overridden the settings on the Graphic Overrides tab will be utilized. Navigate to this tab next.

Verify the settings for each phase category appear as needed:

Video Example

2. View Filters in Use

A view filter will override phasing settings so ensure to check if there is one in place under Visibility / Graphic Overrides > Filters:

Video Example

3. Wall Height

Unconnected Walls below 6'-0" will not appear as cut in the view; this is important to keep in mind if you have a specific line setting which is not being displayed for some walls.

Verify the wall height to see if it falls under this category as it may be a display, and not a phasing setting:

Video Example

Source: Troubleshooting Wall Phasing - The Revit Clinic


0 comments:

  © Blogger template ProBlogger Template by Ourblogtemplates.com 2008

Back to TOP  

[Valid Atom 1.0]